16 research outputs found

    ISIS2: Pixel Sensor with Local Charge Storage for ILC Vertex Detector

    Full text link
    ISIS (In-situ Storage Imaging Sensor) is a novel CMOS sensor with multiple charge storage capability developed for the ILC vertex detector by the Linear Collider Flavour Identification (LCFI) collaboration. This paper reports test results for ISIS2, the second generation of ISIS sensors implemented in a 0.18 micron CMOS process. The local charge storage and charge transfer were unambiguously demonstrated.Comment: 11 pages, 16 figures, to be included in the Proceedings of International Linear Collider Workshop 201

    i3PosNet: Instrument Pose Estimation from X-Ray in temporal bone surgery

    Full text link
    Purpose: Accurate estimation of the position and orientation (pose) of surgical instruments is crucial for delicate minimally invasive temporal bone surgery. Current techniques lack in accuracy and/or line-of-sight constraints (conventional tracking systems) or expose the patient to prohibitive ionizing radiation (intra-operative CT). A possible solution is to capture the instrument with a c-arm at irregular intervals and recover the pose from the image. Methods: i3PosNet infers the position and orientation of instruments from images using a pose estimation network. Said framework considers localized patches and outputs pseudo-landmarks. The pose is reconstructed from pseudo-landmarks by geometric considerations. Results: We show i3PosNet reaches errors less than 0.05mm. It outperforms conventional image registration-based approaches reducing average and maximum errors by at least two thirds. i3PosNet trained on synthetic images generalizes to real x-rays without any further adaptation. Conclusion: The translation of Deep Learning based methods to surgical applications is difficult, because large representative datasets for training and testing are not available. This work empirically shows sub-millimeter pose estimation trained solely based on synthetic training data.Comment: Accepted at International journal of computer assisted radiology and surgery pending publicatio

    Modeling of Charge Transfer Inefficiency in a CCD with High Speed Column Parallel Readout

    Full text link
    Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. An Analytic Model has been developed for the determination of the charge transfer inefficiency (CTI) of a CPCCD. The CTI values determined with the Analytic Model agree largely with those from a full TCAD simulation. The Analytic Model allows efficient study of the variation of the CTI on parameters like readout frequency, operating temperature and occupancy.Comment: 5 pages, 13 figures, presented on behalf of the LCFI Collaboration, proceedings IEEE 2008 Nuclear Science Symposium, Dresden, Germany, and 11th Topical Seminar on Innovative Particle and Radiation Detectors (IPRD08) 2008, Siena, Ital

    i3PosNet: instrument pose estimation from X-ray in temporal bone surgery

    No full text
    PURPOSE:Accurate estimation of the position and orientation (pose) of surgical instruments is crucial for delicate minimally invasive temporal bone surgery. Current techniques lack in accuracy and/or line-of-sight constraints (conventional tracking systems) or expose the patient to prohibitive ionizing radiation (intra-operative CT). A possible solution is to capture the instrument with a c-arm at irregular intervals and recover the pose from the image. METHODS:i3PosNet infers the position and orientation of instruments from images using a pose estimation network. Said framework considers localized patches and outputs pseudo-landmarks. The pose is reconstructed from pseudo-landmarks by geometric considerations. RESULTS:We show i3PosNet reaches errors [Formula: see text] mm. It outperforms conventional image registration-based approaches reducing average and maximum errors by at least two thirds. i3PosNet trained on synthetic images generalizes to real X-rays without any further adaptation. CONCLUSION:The translation of deep learning-based methods to surgical applications is difficult, because large representative datasets for training and testing are not available. This work empirically shows sub-millimeter pose estimation trained solely based on synthetic training data

    Modeling of radiation hardness of a CCD with high-speed column parallel readout

    No full text
    Charge Coupled Devices (CCDs) have been successfully used in several high energy physics experiments over the past two decades. Their high spatial resolution and thin sensitive layers make them an excellent tool for studying short-lived particles. The Linear Collider Flavour Identification (LCFI) collaboration is developing Column-Parallel CCDs (CPCCDs) for the vertex detector of a future Linear Collider. The CPCCDs can be read out many times faster than standard CCDs, significantly increasing their operating speed. Radiation hardness is an important aspect in the CCD development. Bulk radiation damage in the silicon leads to electron traps and hence to charge transfer inefficiency (CTI). The effects of the two trap levels 0.17 and 0.44 eV are considered. We have extended our Analytic Model to include the effects of the shape of the signal charge packet and the clock voltage on the CTI determination. The CTI values determined with the Analytic Model largely agree with those from a full TCAD simulation

    Venous thromboembolism risk and prophylaxis in hospitalised medically ill patients The ENDORSE Global Survey

    No full text
    Limited data are available regarding the risk for venous thromboembolism (VIE) and VIE prophylaxis use in hospitalised medically ill patients. We analysed data from the global ENDORSE survey to evaluate VTE risk and prophylaxis use in this population according to diagnosis, baseline characteristics, and country. Data on patient characteristics, VIE risk, and prophylaxis use were abstracted from hospital charts. VTE risk and prophylaxis use were evaluated according to the 2004 American College of Chest Physicians (ACCP) guidelines. Multivariable analysis was performed to identify factors associated with use of ACCP-recommended prophylaxis. Data were evaluated for 37,356 hospitalised medical patients across 32 countries. VIE risk varied according to medical diagnosis, from 31.2% of patients with gastrointestinal/hepatobiliary diseases to 100% of patients with acute heart failure, active noninfectious respiratory disease, or pulmonary infection (global rate, 41.5%). Among those at risk for VTE, ACCP-recommended prophylaxis was used in 24.4% haemorrhagic stroke patients and 40-45% of cardiopulmonary disease patients (global rate, 39.5%). Large differences in prophylaxis use were observed among countries. Markers of disease severity, including central venous catheters, mechanical ventilation, and admission to intensive care units, were strongly associated with use of ACCP-recommended prophylaxis. In conclusion, VIE risk varies according to medical diagnosis. Less than 40% of at-risk hospitalised medical patients receive ACCP-recommended prophylaxis. Prophylaxis use appears to be associated with disease severity rather than medical diagnosis. These data support the necessity to improve implementation of available guidelines for evaluating VIE risk and providing prophylaxis to hospitalised medical patients

    Venous Thromboembolism Risk and Prophylaxis in the Acute Care Hospital Setting (ENDORSE Survey) Findings in Surgical Patients

    No full text
    Objective: To evaluate venous thromboembolism (VTE) risk in patients who underwent a major operation, including the use of, and factors influencing, American College of Chest Physicians-recommended types of VTE prophylaxis
    corecore